Industrial filtration knowledge base

Practical guidance for process engineers, maintenance teams, environmental specialists and procurement: from input data and technology selection to troubleshooting, service and specification writing.

16guides
8selection tables
18technical terms
17FAQ answers
FIND A GUIDE

Guides

Pick a guide by equipment, contaminant, media, grade or industry: each one carries a selection table and a checklist.

Choosing a dust collection system

Cyclone, baghouse, cartridge collector, scrubber or ESP — a selection table by dust, temperature and duty.

Open
Baghouse or cartridge collector

Compact fine-dust duty versus high loading, temperature and severe operation — how to compare the two technologies.

Open
Filter bag media

A filter bag media selection matrix by temperature, gas chemistry, moisture, abrasion and specialist finishes.

Open
Air filter classes

Why legacy grades cannot be mechanically converted to new ones and what a test report must show.

Open
Cartridge shape and media

Cylinder, cone and oval designs; cellulose, spunbond, nanofibre, PTFE and antistatic media — the air cartridge type table.

Open
Natural gas filtration stages

Stages for particles, condensate and oil aerosols upstream of pressure reduction stations, burners, compressors and turbines.

Open
Gas turbine intake air

Static and pulse-jet systems, V-cell, coalescing and hydrophobic elements for dust, salt and fog.

Open
Choosing a filter press

Chamber, membrane, automatic or tower — selecting the press type by slurry, cycle, cake moisture and discharge.

Open
Filter press cloths

PP, PET, PA and weave type: selecting filter press cloth by chemistry, abrasion, particle size, permeability, cake release and washing.

Open
CEMS/AQMS architecture

From probe to emissions report: sampling, line, conditioning, analysers, DAHS, calibration, quality assurance and archive.

Open
Water treatment checklist

Water treatment and online monitoring checklist: analysis, water balance, mechanical, membrane and chemical stages, monitoring points and service.

Open
Troubleshooting

Symptom → cause → check → action: a matrix for high ΔP, dust leakage, short life, wet cake and unstable measurements.

Open
Panel, pocket, V-bank or HEPA

Selecting a ventilation filter for AHUs and clean areas: grade cascade, dust holding, dimensions, airflow and allowable ΔP.

Open
Compressor filtration chain

From intake to point of use: air, oil, separator, dryer, coalescer and ISO 8573-1 purity classes.

Open
Pleated bag or cartridge

Why a high-temperature pleated bag is not a standard cartridge and what to check before retrofitting a baghouse.

Open
Cartridge temperature limit

Why the standard cartridge maximum is 135 °C: media, adhesive, end caps, cage and gasket are rated as one assembly; the PET samples state 120 °C continuous.

Open
DOCUMENTS AND TOOLS

Standards and calculators

An overview of the Oʻz MSt 194/195:2024 standards and engineering calculators for a preliminary estimate.

METHOD

From the problem to a sound specification

Reliable selection begins with verified process data and equal supply boundaries for every quotation, not with a model number.

  1. 01Define the duty

    Normal, minimum, maximum and upset duty, operating hours and seasonality.

  2. 02Characterise the contamination

    Composition, loading, particle size, stickiness, abrasion, moisture and explosion risk.

  3. 03Set the target

    Outlet concentration or grade, service life, allowable ΔP, cake moisture and equipment availability.

  4. 04Verify integration

    Footprint, foundations, utilities, instrumentation, interfaces, hazardous area, maintenance and dismantling.

  5. 05Compare like for like

    Scope, performance guarantees, consumables, installation, commissioning, training and lifecycle cost.

GLOSSARY

18 terms used in specifications

TermDefinition
ΔPPressure difference between inlet and outlet; a filter loading indicator.
A/C ratioGas flow divided by cloth area, commonly m/min.
Nm³/hFlow referenced to stated normal conditions.
Dust loadingDust mass per gas volume, commonly g/m³, with size distribution.
Dew pointTemperature at which condensation starts; below it blinding and corrosion may occur.
Pulse-jet cleaningElement regeneration by a short pulse of compressed air.
ePTFE membraneExpanded PTFE; a fine membrane for surface filtration.
ISO ePM1ISO 16890 efficiency group referenced to the PM1 fraction.
MPPS sizeParticle size at which a HEPA filter shows its minimum efficiency.
CoalescenceCombining fine droplets into larger drops for separation and drainage.
CakeSolids layer formed on the cloth during filtration.
FiltrateLiquid that has passed through the filter press cloth.
Membrane squeezeAdditional cake compression by a membrane after chamber filling.
CEMSContinuous emissions monitoring system for a stationary source.
AQMSAmbient air quality monitoring system.
DAHS systemAcquisition, validation, storage and reporting of analyser data.
Ex / ATEX ratingHazardous-area equipment requirements; applicability is confirmed by the project.
Lifecycle costPurchase, energy, utilities, consumables, downtime, service and disposal.
FAQ

Frequently asked engineering questions

What data is needed for preliminary selection?

At minimum: flow, temperature, pressure, contaminant composition and loading, target result, duty, allowable ΔP and a photo or drawing of the installation point.

How does a cartridge collector differ from a baghouse?

Cartridges are compact and suit dry fine dust. Baghouses are often better for high loading, hot gas and severe continuous duty.

How should G4, F7, F9 and ISO ePM1 be compared?

Identify the standard first. G/F are legacy EN 779 grades; ISO ePM belongs to ISO 16890. There is no exact universal conversion: compare test reports at equal airflow and ΔP.

Which filter is needed upstream of a gas burner?

A 10–50 μm cartridge is common, but the burner or valve manufacturer and the project set the requirement. Verify DN, PN, flow, ΔP, temperature, drainage and contamination.

When does a gas turbine need pulse-jet filtration?

For high dust, storms and cleaning without shutdown. Consider climate, particle distribution, humidity, compressed air, efficiency and allowable inlet ΔP.

How can incorrect filter media be recognised?

Signs include rapid ageing, shrinkage, hydrolysis, burns, blinding, high residual ΔP, poor cake release or unstable emissions. Analyse the element and the duty history.

How is filter press cloth selected?

By pH, temperature, solvent, abrasion, particle size, filtrate clarity, cake release and cleaning method. Test several cloths for a new slurry.

What is included in CEMS/AQMS service?

Probe and line, consumables, flow and leak checks, zero/span, calibration, DAHS and communications, backup, service record and recommendations. Scope follows the quality method.

Why are there no fixed prices?

Price depends on capacity, materials, pressure, controls, installation and logistics. Compare quotations only after equal supply boundaries are defined.

Can you match an OEM reference?

Yes — once dimensions, seal, media, grade or rating, flow and conditions are confirmed. A code alone, without checking the parameters, can lead to a wrong selection.

Can I start with an online calculation?

Yes. Calculators provide an initial estimate but do not replace design calculations, safety review or manufacturer data.

Do you work outside Uzbekistan?

Yes, across Central Asia and the CIS. Logistics, certification, installation and service are defined for each country and site.

Which files should be attached to an enquiry?

The specification, datasheet, OEM reference, drawing, nameplate and mounting photos, process analysis, duty map and recent ΔP, emissions or filtrate data.

Can an existing system be upgraded?

Yes — after auditing the housing, fan or pump, hydraulics, controls, site and actual duty. Media, compartments, pulse system, instrumentation, washing or membrane plates can be replaced.

What is the maximum temperature of an air cartridge?

This site limits a complete standard cartridge assembly to 135 °C maximum. Many supplied PET samples state 120 °C continuous. The final value is always confirmed by the complete-assembly datasheet.

Which elements belong in screw compressor maintenance?

Normally the intake air filter, oil filter and air-oil separator, subject to model and interval. Downstream coalescing filters, the dryer and automatic drains are checked separately.

Why is a pleated bag treated separately?

It fits a baghouse tube sheet and follows different geometry and cleaning checks. Its high-temperature media ratings cannot be automatically applied to a standard cartridge.

NEED AN ENGINEERING REVIEW?

Send process data and receive a solution map

We review the specification, identify missing measurements and propose a process arrangement and supply scope.