0%
INDUSTRIAL FILTRATION · 3D
PHOENIX PRIME
GUIDE

Why the cartridge maximum is 135 °C

Media, adhesive, end caps, cage and gasket are rated as one assembly; the supplied PET samples state 120 °C for continuous duty.

THE RULE

Temperature: media versus assembly

This site limits a standard cartridge element to 135 °C maximum. The supplied PET sheets state 120 °C continuous. Even if a fibre tolerates more, adhesive, end caps, cage and gasket may limit the completed product. A substrate sheet therefore does not replace a cartridge assembly datasheet.

Values of 180–260 °C belong to selected baghouse or pleated-bag media and must not be applied to a standard cartridge. Acids, alkalis, oxygen and hydrolysis can also reduce the allowable duty.

MEDIA

Substrate, surface layer and finish work together

Temperatures shown are typical guidance, not a guaranteed rating. The final limit must be confirmed for the media, adhesive, end caps and gasket as an assembly.

Media / finish
01 / 08Cellulose
Typical duty
Dry coarse and medium dust at moderate loading
Benefit
Economical with high media area
Check before selection
Humidity, condensation and a typical limit near 80 °C
SAMPLES

Polyester media samples and data sheets

Ten polyester media samples and data sheets serve as the technical selection references: base PET, point-bond, spunbond, BICO, PTFE membrane, antistatic, flame-retardant and water/oil-repellent finishes. Most of the samples (PET-W-X100, PET-W-F180, PET-W-X150, PET-DG-F170, BICO-W-260, PET-W-XJ140) state 120 °C for continuous duty.

Values apply to the specific sample; the production batch and datasheet are verified before supply. PHOENIX PRIME does not present the sample maker as an official partner.

Q&A

Frequently asked questions

What is the maximum temperature of an air cartridge?

This site limits a complete standard cartridge assembly to 135 °C maximum. Many supplied PET samples state 120 °C continuous. The final value is always confirmed by the complete-assembly datasheet.

Why cannot 200 °C be applied to a standard cartridge?

Because it may be a fibre-only limit, while a standard cartridge is also limited by adhesive, end caps, cage and gasket. This site sets 135 °C as the maximum for a standard cartridge.

Why is a pleated bag treated separately?

It fits a baghouse tube sheet and follows different geometry and cleaning checks. Its high-temperature media ratings cannot be automatically applied to a standard cartridge.

3D MODELS

Cartridge shapes in 3D

RELATED PAGES

On this topic

An engineer will answer your question