0%
INDUSTRIAL FILTRATION · 3D
PHOENIX PRIME
GUIDE

Panel, pocket, V-bank or HEPA

Selection by grade cascade, dust holding, dimensions, airflow and allowable pressure drop for AHUs and clean areas.

CASCADE

How to build a ventilation cascade

The first stage removes coarse dust, the intermediate stage protects the final filter and the final stage delivers the target cleanliness. The cascade is built so that the higher-value final stage does not take the coarse dust and does not reach its terminal pressure drop quickly.

Check the solution against total ΔP, dust holding, moisture, frames and fan capacity. G3–F9 identify legacy requirements; a new selection needs test evidence to the applicable ISO 16890 edition, and there is no universal direct conversion between grades.

FORM FACTORS

From prefilter to final stage

GRADES

Legacy labels are shown alongside test data

G3–F9 labels help identify existing replacements, while project selection uses test data to the applicable ISO 16890 edition, airflow and ΔP.

Label
01 / 05G3 / G4
Typical role
Coarse prefiltration
Construction
Panel, cell or pocket
Verify
Dust holding, moisture and fire behaviour

Temperature and humidity are confirmed by the specific filter datasheet. A media limit must not be applied to the complete cell: frame, sealant, separator and gasket may impose a lower rating.

SELECTION

Data for a replacement or a new design

  1. 01Size

    Width, height, depth, frame, number of pockets and gasket.

  2. 02Air

    Airflow, temperature, humidity, outdoor or recirculated duty.

  3. 03Requirement

    Grade, test report, allowable ΔP, final cleanliness and service life.

  4. 04System

    AHU model, fan, frames, number of stages and service access.

Q&A

Frequently asked questions

Can F7 be directly replaced by ePM1?

There is no universal conversion. G/F are legacy EN 779 grades; ISO ePM belongs to ISO 16890. Compare the product test report, airflow, initial and terminal ΔP, dimensions and the project requirement.

Is a pocket or a V-bank filter better?

Pockets offer economical dust holding; V-bank cells provide high area and stable geometry in a compact depth. Space, moisture, ΔP and lifecycle cost decide.

Why does a filter collapse or tear?

Potential causes include excess airflow, a blocked stage, a weak frame, wetting, wrong orientation or missing support. Inspect both the aerodynamics and the installation.

When is HEPA required?

When the final cleanliness and the process risk assessment require a high-efficiency final stage. HEPA must come with a verified class and installation leak-tightness control.

RELATED PAGES

On this topic

An engineer will answer your question

We review the specification, identify missing measurements and propose a process arrangement and supply scope.